Customization: | Available |
---|---|
Display Type: | Site Display |
Connection Type: | Flange Type |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | 8732E |
Type | Flow Meter Electronics (Transmitter/Indicator) |
Display | - Dual-line, backlit LCD with 14-character lines - Configurable to show flow rate, total, percentage, or custom messages - User-friendly interface with intuitive navigation keys |
Communication Protocols | -Standard: 4-20 mA analog output with HART® 7 -Optional: FOUNDATION™ Fieldbus, PROFIBUS PA, Modbus RTU (via RS485) - Supports digital diagnostics and remote configuration |
Input Signals | From Rosemount 8700 series magnetic flow sensors (voltage proportional to flow velocity) |
Outputs | - 2 x 4-20 mA analog (flow rate and total, configurable) - 2 x solid-state relays (for alarms, totals, or pulse outputs) - Pulse output (configurable as flow total or frequency) - Digital communication (as per protocol selected) |
Power Supply | -AC: 100-240 VAC, 50/60 Hz, ±10% -DC: 24 VDC (16-36 VDC), ±15% |
Electrical Protection | - Surge protection ( IEC 61000-4-5) - Reverse polarity protection for DC supply - Overvoltage protection for analog outputs |
Environmental Ratings | -Housing: NEMA 4X (IP66/IP67), aluminum or stainless steel -Temperature: - Operating: -40°C to +60°C (-40°F to +140°F) - Storage: -40°C to +85°C (-40°F to +185°F) -Humidity: 5-95% RH (non-condensing) |
Explosion Ratings | - Intrinsic Safety (IS): ATEX, IECEx, FM, CSA, NEPSI - Non-incendive: ATEX, IECEx, FM, CSA |
Certifications & Compliance | - CE, CSA, FM, RoHS, WEEE - Compliance with NACE MR0175 (for sour gas applications, optional) - Meets IEC 61508 (SIL 2 capable, when configured with appropriate sensors) |
Configuration | - Local configuration via keypad or HART® communicator - Remote configuration via fieldbus or AMS Device Manager |
Diagnostics | - Advanced self-diagnostics (sensor failure, liner damage, low conductivity, etc.) - Asset management diagnostics (via HART® or fieldbus) - Display of diagnostic codes and status messages |
Mounting Options | - Remote mount (up to 300 m/984 ft from sensor) - Integral mount (directly attached to sensor, optional) |
Language Support | English, Spanish, French, German, Chinese, Japanese, Korean, and others (configurable) |
Weight | - Aluminum housing: ~4.5 kg (~9.9 lbs) - Stainless steel housing: ~6.8 kg (~15 lbs) |
Warranty | 1 year standard |