Parameter |
Specification |
Model |
248RANA, 248RANAQ4 (common variants) |
Input Types |
RTD, thermocouple (T/C), mV, ohms (universal sensor support) |
Communication Protocol |
HART® 7 protocol (standard); WirelessHART® (optional for wireless models) |
Mounting Options |
DIN rail, head-mounted, or field-mounted (three housing options) |
Enclosure Material |
Aluminum, stainless steel (SST), or polypropylene (IP66/68 rated) |
Power Supply |
12-42 V DC (HART); 10.5-42 V DC (WirelessHART) |
Output Signal |
4-20 mA with HART digital signal; WirelessHART (for wireless models) |
Accuracy |
±0.1% of span (ambient temperature compensated) |
Ambient Temperature Range |
-40°C to 85°C (-40°F to 185°F) |
Process Temperature Range |
Depends on sensor type (RTD: -200°C to 850°C; T/C: -200°C to 1372°C) |
Certifications |
SIL 2 (IEC 61508), ATEX, IECEx, FM, CSA, EAC |
Diagnostics |
Open/short sensor detection, environmental compensation, four configurable alarms |
Stability |
±0.1% per year (guaranteed) |
Calibration |
On-site calibration via 375 Field Communicator; optional three-point certificate |
Enclosure Options |
DIN B head, universal junction box, sanitary connection heads (DIN A/B) |
Environmental Protection |
IP66/IP68 (depending on enclosure) |
Assembly Options |
Pre-assembled with sensor, thermowell, and accessories (model-specific) |