High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer

Product Details
Customization: Available
After-sales Service: One-Year Warranty
Warranty: One-Year Warranty
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (18)
  • High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer
  • High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer
  • High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer
  • High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer
  • High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer
  • High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
CCS141
Display
Digital
Appliance
Biochemistry
Portable
Portable
Certification
FCC, CE, ISO9001
Type
Conductivity Meter
Item Name
Mettler Toledo M200 Liquid Analyzer
MOQ
1PC
Customized Support
OEM, ODM
Infrared Resolution
Other
Brand Name
E+H
Thermal Color Palettes
Black
Material
Plastics
Place of Origin
Germany, China
Output
4 ~20mA Hart
Measuring Range
0 to 100 Deg C
Housing
Dual-Compartment Field Mount
Single Package Size
15*15*15 Cm
Single Gross Weight
2.00 Kg
Selling Units
Single Item
Condition
Fresh/Semi-Fresh
Transport Package
Carton Boxes
Specification
10*10*10cm
Trademark
METTLER TOLEDO
Origin
Switzerland, China
HS Code
90262000
Production Capacity
100/Month

Packaging & Delivery

Package Size
15.00cm * 15.00cm * 15.00cm
Package Gross Weight
2.000kg

Product Description

Product Description
The High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer represents a pinnacle of precision engineering in the field of water treatment process analytics, designed explicitly to measure trace levels of chlorine with exceptional accuracy in industrial settings. Manufactured by Endress+Hauser, a globally recognized pioneer in process measurement and automation technologies, the CCS141 embodies the company's legacy of innovation, reliability, and technical excellence, making it an indispensable instrument for industries where precise chlorine monitoring is critical to water quality, process efficiency, and regulatory compliance.
High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer

At its core, the CCS141 is engineered to detect and quantify trace amounts of chlorine, including free chlorine, total chlorine, and monochloramine, depending on the specific configuration, in a wide range of industrial water treatment applications. Chlorine, widely used as a disinfectant in water treatment processes, plays a vital role in eliminating harmful microorganisms, preventing biofouling, and ensuring the safety of water for various industrial uses, such as cooling water systems, boiler feedwater, process water, and wastewater discharge. However, maintaining chlorine at optimal trace levels is paramount-excessive concentrations can lead to corrosion of equipment, formation of harmful byproducts, and environmental harm, while insufficient levels may compromise disinfection efficacy, increasing the risk of microbial contamination. The CCS141 addresses this balance by providing high-precision measurements, enabling operators to maintain tight control over chlorine levels with confidence.

Features

The measurement principle employed by the CCS141 is tailored to the detection of trace chlorine, leveraging advanced electrochemical or colorimetric technology, depending on the application requirements. Electrochemical sensors, often used for real-time monitoring, work by measuring the current generated by the electrochemical reaction of chlorine with the sensor's electrode, a method known for its sensitivity and rapid response times-critical attributes when dealing with trace concentrations. Colorimetric methods, on the other hand, utilize chemical reagents that react with chlorine to produce a color change, whose intensity is measured photometrically to determine chlorine levels. This versatility in measurement principles allows the CCS141 to adapt to different water matrices and chlorine forms, ensuring accurate results across diverse industrial scenarios.
High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer

Industrial Process Control

The CCS141's design is optimized for rugged industrial environments, where durability and reliability are non-negotiable. Its housing is constructed from robust materials, such as stainless steel or high-grade plastics, resistant to corrosion, mechanical impact, and exposure to harsh chemicals often found in industrial facilities. This ruggedness ensures that the analyzer can withstand the rigors of continuous operation in environments with high humidity, temperature fluctuations, and airborne contaminants, maintaining consistent performance over extended periods. Additionally, the wetted parts of the analyzer-those in direct contact with the water sample-are made from materials compatible with chlorine and other disinfectants, preventing degradation and ensuring long-term measurement stability.In terms of operational parameters, the CCS141 is designed to function efficiently across a range of process conditions typical in industrial water treatment. The process temperature range is typically between 0 °C and 40 °C (32 to 104 °F), covering the thermal conditions encountered in most cooling, boiler, and process water systems. The analyzer can also handle varying sample flow rates, with built-in flow control mechanisms to ensure a consistent sample supply, a critical factor for reliable measurements. Pressure tolerance is another key consideration, with the CCS141 capable of operating under moderate process pressures, typically up to 10 bar (145 psi), making it suitable for integration into pressurized water systems without the need for additional pressure regulation equipment.A standout aspect of the CCS141 is its advanced connectivity and integration capabilities, aligning with modern industrial automation standards. The analyzer is equipped with a range of digital communication protocols, such as HART, Profibus, Modbus, and Ethernet/IP, enabling seamless integration into existing distributed control systems (DCS), supervisory control and data acquisition (SCADA) systems, and industrial internet of things (IIoT) platforms. This connectivity facilitates real-time data transmission, allowing operators to monitor chlorine levels remotely, set up automated alarms for deviations from target concentrations, and integrate chlorine data with other process parameters-such as pH, conductivity, or flow rate-for a comprehensive view of water quality. The ability to transmit data digitally also reduces the risk of signal loss or interference compared to analog systems, ensuring that measurement data remains accurate and reliable even over long distances.
High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer
High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer
High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer
High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer
Product Parameters
Place of Origin Germany,China Warranty 1 Year
Customized Support OEM, ODM, OBM Brand Name Endress+Hauser
 Material   plastic   Color   Black 
 Power   Other   Selling Units   Single item 
 Single gross weight   2.000 KG   Single package size   10X20X20 cm 
 Outputs   4-20 mA HART   Model   CCS141 
 Condition   100% Original brand new and High Quality   Shipping   By DHL\UPS\Fedex 
 MOQ   1pc   Packaging and delivery   Carton Boxes 
Packaging & Shipping

High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer

Carton Boxes
Company Profile

KeRui (Weifang) Automation Equipment Co., Ltd.Specializes in industrial automation instrument development, production and sales, technical services, and supporting equipment supply to specialized companies. The main products are flow meters, level meters, temperature meters, pressure meters, electrical meters, thermal intelligent meters, programmable controllers (PLC), DCS distributed control systems, and eight series of more than 1,000 specifications. Its products and technologies are widely used in electric power, metallurgy, petrochemicals, environmental protection, plastics, food, printing, tobacco, textile, dyeing, and other fields.High Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine AnalyzerHigh Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine AnalyzerHigh Accuracy E+H CCS141 Industrial Process Control Water Treatment Trace Chlorine Analyzer

FAQ

 1.Q: How long is the delivery?
 -- Mostly within 10days
 2.Q:Can I get a sample? 
 --  Sure, contact our sales please
 3.Q:What is your MOQ? 
 --  1pcs
 4.Q: How about warranty time? 
 -- 12month
 5.Q: How can I visit your factory?
 -- Fly to Qingdao air port, it's our pleasure to pick you up.
 6.Q:How do you control your quality ? 
 -- We have EPR system .we control from parts, process, testing, packing ,retesting.
 Every Sensor will be tested two times before reach you, after that sport test for the third time. Make sure about the quantity.

Send your message to this supplier