Basic Info.
Model NO.
Rosemount 3051GP
Type
Differential Pressure Transmitter
Structure Type
Strain Gauge Pressure Transmitter
Customized Support
OEM, ODM, Obm
Model Number
Rosemount 3051gp
Typee
Pressure Transmitter
Brand Namee
Emerson Rosemounte
Keywords
100% Original Brand New Fast Delivery
Communication Protocol
4~20 Ma Hart
Electric Power
Boiler Steam Pressure Control
Level of Protection
IP66/IP68 (NEMA 4X)
Optional
Foundation Fieldbus
Transport Package
Original Product
Specification
20cm*20cm*20cm
Product Description
Product Description
Product Name | Rosemount 3051GP |
Brand Name | Rosemount |
Warranty | 1 Year |
Website | KeRui(WeiFang)AutomationEquipment Co.,Ltd |
Detailed Photos
Product Parameters
The Rosemount 3051GP Pressure Transmitter is a high-performance, industrial-grade device designed for precise pressure measurement in demanding applications. Below is a comprehensive breakdown of its technical parameters, features, and capabilities.
1. General Specifications
Model:Rosemount 3051GP (Gauge Pressure Transmitter).
Manufacturer:Emerson Process Management.
Sensor Technology:Advanced capacitive sensor with silicon-filled isolation.
Output Signal:4-20 mA DC, HART® 5/7, FOUNDATION™ Fieldbus, or PROFIBUS PA (configurable).
Power Supply:10.5-55 V DC (HART), 9-32 V DC (Fieldbus), or 12-45 V DC (PROFIBUS PA).
Communication Protocol:HART® 7, FOUNDATION Fieldbus H1, or PROFIBUS PA.
Display:Optional LCD with 4-6 lines of text (local configuration and diagnostics).
Enclosure Rating:NEMA 4X (IP66, IP67, IP68) with aluminum or stainless steel housing.
Certifications:ATEX, IECEx, FM, CSA, CE, UKCA, SIL 2/3 (Functional Safety).
2. Performance Specifications
Accuracy
Reference Accuracy:±0.075% of calibrated span (includes linearity, hysteresis, and repeatability).
Total Performance:±0.1% of URL (Upper Range Limit) over 1 year, including temperature and static pressure effects.
Long-Term Stability:±0.1% of URL per 5 years.
Pressure Ranges
Gauge Pressure (GP) Range:
Minimum Span: 0.5 kPa to 2.5 kPa (dependent on model).
Maximum Span: Up to 41 MPa (6,000 psi).
Overpressure Limit: 1.5× URL (burst pressure up to 3× URL).
Temperature Limits
Process Temperature:
Standard: -40°C to 85°C (-40°F to 185°F).
Extended: -90°C to 110°C (-130°F to 230°F) with optional isolators.
Ambient Temperature:
Operating: -40°C to 85°C (-40°F to 185°F).
Storage: -50°C to 100°C (-58°F to 212°F).
Response Time
Damping adjustable from 0-60 seconds (default: 0.4 seconds).
3. Electrical Specifications
Loop Resistance:
HART: 250-1,100 Ω at 20 mA.
Fieldbus/PROFIBUS: Compliant with bus requirements.
Isolation:
Input-to-output: 500 V AC RMS.
Input-to-ground: 500 V AC RMS.
Surge Protection:IEC 61000-4-5 (1.2/50 µs) up to 2.5 kV.
4. Mechanical Specifications
Materials
Wetted Parts:Process Diaphragm: 316L SST, Hastelloy® C-276, or tantalum.
Housing:Aluminum (standard) or stainless steel (optional).
Mounting:2-inch pipe mount or direct manifold.
Process Connections
Standard:1/4-inch NPT, 1/2-inch NPT, or G 1/2.
Optional:ANSI/ASME B16.5 flanges (1/2-inch to 2-inch), DIN 11851, or others.
Seal Options:Threaded, flange, or sanitary connections.
Weight
Aluminum housing: 2.7 kg (6.0 lb).
Stainless steel housing: 3.6 kg (8.0 lb).
5. Environmental and Operational Compliance
EMI/RFI Immunity:Compliant with IEC 61326-1, CISPR 11.
Vibration Resistance:5 g RMS (2-150 Hz).
Shock Resistance:50 g (11 ms).
Humidity:0-100% RH (non-condensing)
6. Advanced Diagnostics and Features
Diagnostics:
Sensor health monitoring.
Process condition alerts (overpressure, temperature extremes).
Plugged impulse line detection (optional).
HART® Features:
Digital trimming and calibration.
Device status, configuration, and history via AMS Suite, FieldCare, or handheld communicator.
SIL Compliance:
SIL 2 (Hardware Fault Tolerance ≥ 1).
SIL 3 (with redundant configurations).
7. Calibration and Configuration
Range Adjustment:Turndown ratio up to 100:1.
Calibration:Traceable to NIST standards.
Configuration:Via local LCD, HART® handheld, or software (Rosemount 375/475, AMS Device Manager).
8. Application-Specific Options
Oxygen Service:Cleaned and packaged for O2 compatibility (ASTM G93).
Sanitary Compliance:3-A, EHEDG, FDA-approved materials.
High Static Pressure:Available for pipeline and hydraulic systems.
9. Ordering Information
Base Model:3051GP followed by suffix codes (e.g., 3051GP3A2B3C4D5).
Suffix Codes:Define output, process connection, materials, and certifications.
10. Maintenance and Service
MTBF (Mean Time Between Failures):> 470 years (calculated per IEC 61508).
Warranty:5-year limited warranty.
Service Support:Global Emerson service network with calibration and repair.
Installation Instructions
1. Installation LocationAvoid excessive vibration, temp extremes, and direct sunlight.
Mount vertically (process connection downward) to prevent condensate accumulation.
Ensure easy access for calibration/maintenance.
2. Process ConnectionUse compatible flanges/gaskets per process media (check material specs).
Torque flange bolts evenly to manufacturer specs (avoid over-tightening).
Isolate from line shock using valves/pulsation dampeners.
3. Electrical ConnectionsPower supply: 10.5-42 V DC (loop-powered).
Polarity: "+" to terminal 1, "-" to terminal 2.
Use shielded twisted-pair cable; ground shield at one end (DCS/PLC side).
Ensure conduit seals for hazardous areas (Ex certifications).
4. CommissioningZero calibration: Vent both ports (for gauge/differential models) and adjust via local button/HART.
Span calibration: Apply known pressure and trim using HART communicator (375/475).
Verify 4-20 mA output correlates with applied pressure.
5. ConfigurationSet range (URL/LRL) via HART.
Configure units (psi, bar, etc.), damping, and failure mode (upscale/downscale).
Enable diagnostics (sensor/electronics health).
6. Safety & MaintenanceIsolate process pressure before servicing.
Inspect seals/gaskets annually; replace if corroded/worn.
Recalibrate every 12-24 months or per process criticality.
Key NotesAvoid overpressure: Check max pressure rating vs. process.
Use compatible wetted materials for corrosive media.
Ensure proper grounding to prevent EMI/noise.
Packaging & Shipping
Company Profile
After Sales Service
FAQ
Q: How long will you give me the reply?
A: We will reply to you as soon as we see the information
Q: What is the delivery time?
A:The products in stock will be shipped after receiving the payment, and the products that
need to be ordered are subject to the factory time.
Q: How about your package?
A: Do not worry about the package, we have rich experience in packing.
Q: How about the payment terms?
A:You can choose T/T.
Q: What is the MOQ?
A:1PC.
Q: Can l get a lower price if l order large quantities?
A: Yes, cheaper prices with more bigger size orders.
Q:After sales and warranty?
A: We provide one year warranty lifetime technical support services.