Specification Items | Details |
Enclosure Rating | Polycarbonate, Type 4X, IP65 |
Certifications/Approvals | FM/CSA/UL (see full specifications for complete list of certifications) |
Dimensions | Overall: 155 x 155 x 131 mm (6.10 x 6.10 x 5.15 in.); Cutout: 1/2 DIN 139 mm x 139 mm (5.45 x 5.45 in.) |
Weight | 3 lbs/4 lbs (1.5 kg/2.0 kg) |
Conduit Openings | Accepts 1/2” or pg13.5 conduit fittings |
Display | Monochromatic graphic liquid crystal display, 128 x 96 pixel display resolution, backlit, active display area: 58 x 78 mm (2.3 x 3.0 in.) |
Ambient Temperature and Humidity | 0 - 55 °C (32 - 131 °F) for general; 0 - 50 °C (32 - 122 °F) for turbidity only, RH 5 - 95% (non - condensing) |
Storage Temperature | -20 - 60 °C (-4 - 140 °F) |
Power | Code - 01: 115/230 VAC ± 15%, 50/60 Hz, 10 W; Code - 02: 20 - 30 VDC, 15 W; Code - 03: 85 - 265 VAC, 47.5 - 65.0 Hz, switching, 15 W |
Alarm Relays | Four alarm relays for process measurement(s) or temperature (only available with - 02 power supply (20 - 30 VDC) or - 03 switching power supply (85 - 265 VAC)). Any relay can be configured as a fault alarm instead of a process alarm. Each relay can be configured independently and each can be programmed with interval timer settings. Relays: form C, SPDT, epoxy sealed |
Inputs | One or two isolated sensor inputs |
Outputs | Two 4 - 20 mA or 0 - 20 mA isolated current outputs, fully scalable, max load: 550 ohm. Current output accuracy: ±0.05 mA @ 25 ºC |
Terminal Connections Rating | Power connector (3 - leads): 24 - 12 AWG wire size; Signal board terminal blocks: 26 - 16 AWG wire size; Current output connectors (2 - leads): 24 - 16 AWG wire size; Alarm relay terminal blocks: 24 - 12 AWG wire size (- 02 24 VDC power supply and - 03 85 - 265 VAC power supply) |
Communication | HART® and PROFIBUS DP digital communications available |
Measurement Types | pH, ORP, ISE, resistivity, conductivity, percent concentration, chlorine, oxygen, ozone, temperature, turbidity, flow, and 4 - 20 mA current input |