Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| After-sales Service: | Offer After-Sales Service |
| Warranty: | 1 Year |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency







Category | Specification |
Basic Model | CMFS100PA (1"/DN25) |
Measurement Principle | Coriolis |
Measured Variables | Mass flow, density, temperature, volume flow (derived) |
Tube Design | Single straight tube, 316L stainless steel |
Mass Flow Accuracy | ±0.10% of reading (std), ±0.05% (high-accuracy option) |
Density Accuracy | ±0.0005 g/cm³ (liquid) |
Temperature Accuracy | ±0.5°C |
Max Mass Flow Rate | 181,000 kg/h (water) |
Max Volume Flow Rate | ~181 m³/h |
Pressure Rating | ANSI Class 600 (std), higher classes available (confirm full model code) |
Process Temperature Range | -240°C to +204°C (std), up to +427°C (high-temp option) |
Ambient Temperature Range | -40°C to +60°C |
Wetted Materials | 316L SST (std), Hastelloy C-22, Tantalum, etc. (options) |
Seal Materials | Elastomer O-rings (std), metal seals (option) |
Output Signals | 2 channels, 4-20 mA (assignable) |
Digital Protocols | HART 7, FOUNDATION Fieldbus, PROFIBUS PA, Modbus RS485, EtherNet/IP (option) |
Power Supply | 16-50 V DC (analog), 10-32 V DC (digital bus) |
Local Display | Optional integrated backlit LCD (Promecon® interface) |
Zero Stability | Excellent |
Linearity | 0.1% of rate (typical) |
Repeatability | 0.05% of rate (typical) |
Response Time | <100 ms (typical, adjustable) |
Damping Adjustment | 0-100 seconds (software configurable) |
Hazardous Area Certs | ATEX, IECEx, FM, CSA (Division 1 / Zone 1) |
Ingress Protection | NEMA 4X / IP67 |
Process Connections | Flanged (ANSI, DIN, JIS standards) |
Field Calibration | Yes (via transmitter) |