Customization: | Available |
---|---|
Type: | Differential Pressure Transmitter |
Structure Type: | Capacitive Pressure Transmitter |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | valve |
Type | Gauge pressure transmitter |
Measuring Range | Gauge pressure: 0–100 Pa to 0–40 MPa (varies by model; specific ranges include 0–1 kPa, 0–10 kPa, 0–100 kPa, 0–1 MPa, 0–10 MPa, 0–40 MPa, etc.) |
Accuracy | ±0.065% of calibrated span (including linearity, hysteresis, and repeatability) under reference conditions: temperature 15–35°C (59–95°F), static pressure 0 MPa, and ambient pressure 0.1 MPa |
Stability | ±0.1% of URL (Upper Range Limit) per 5 years |
Output Signal | - Standard: 4–20 mA DC with HART® 7 protocol (two-way digital communication, superimposed on the analog signal) - Optional: FOUNDATION Fieldbus (low-voltage mode) or PROFIBUS PA (conforms to IEC 61158-2 and EN 50170 standards) |
Sensor Technology | Monocrystalline silicon resonant sensor; converts pressure into high-frequency resonant signals (≈10 kHz) for digital processing, minimizing drift and interference |
Operating Temperature Range | - Ambient: -40–85°C (-40–185°F) - Process: -30–100°C (-22–212°F) for standard models; up to 130°C (266°F) with optional cooling extension - Storage: -50–100°C (-58–212°F) |
Pressure Limits | - Overpressure: Up to 100 times the calibrated span (varies by range; e.g., 40 MPa for high-range models) without permanent damage, protected by a unique diaphragm design that stops pressure transmission to the sensor when overloaded - Static pressure: Up to 40 MPa (depends on model) |
Wetted Materials | - Diaphragm: Hastelloy® C-276, 316L stainless steel, or tantalum (optional for corrosive media) - Diaphragm chamber: 316L stainless steel - Seal ring: 316L stainless steel (soft type) |
Housing Material | Aluminum (painted) or 316 stainless steel (optional for harsh environments) |
Electrical Connections | - Conduit entries: M20 × 1.5 or ½ NPT (1/2 NPT optional) - Wiring: 2-wire system; terminal block accepts 0.5–2.5 mm² (20–14 AWG) wires |
Ingress Protection | IP66/IP67 (NEMA 4X) for standard models; IP68 optional (for submersible or high-moisture environments) |
Safety Certifications | - Functional safety: SIL 2 compliance (per IEC 61508) - Hazardous areas: ATEX, IECEx, FM, CSA, and UL certifications for explosive atmospheres (Ex ia, Ex d, etc., depending on model) - General: CE marked, RoHS compliant |
Weight | Approximately 3.9 kg (8.6 lb) for standard flange models; varies slightly by process connection type (e.g., threaded, flange) |
Process Connections | Optional flange (ANSI, JIS, DIN), threaded (NPT, BSP), or sanitary connections (for food/pharmaceutical applications) |
Diagnostics | Built-in self-diagnostic functions (via HART/Fieldbus) including sensor errors, overrange/underrange alerts, temperature deviations, and communication faults; supports remote monitoring of device health |