Customization: | Available |
---|---|
Type: | Lightning Protection Type |
Structure Design: | Flange Type |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Endress+Hauser Minicap FTC260 Capacitive Level Detector | |
Parameter | Specification |
Measuring principle | Capacitive Solid |
Characteristic / Application | Compact rod probe with build-up compensation |
Specialities | FDA-listed material |
Supply / Communication | 10,8 ... 45V DC, DC-PNP 3-wire 20 ... 253V AC, or 20 ... 55V DC, Relay output |
Ambient temperature | -40°C...+70 °C(-40°F...+158°F) |
Process temperature | -40°C ...+120°C (-40°F ...+248°F) |
Process pressure / max. overpressure limit | -1 ... 25 bar (-14.5 ... 360 psi) |
Main wetted parts | PPS = Polyphenylene sulphide (glass fibre content approx. 40%) |
Process connection | R1" NPT1" |
Sensor length | 140 mm (5.51") |
Communication | PNP transistor output Relay output (potential-free change-over contact / SPDT) |
Certificates / Approvals | ATEX , IEC Ex, FM, CSA, NEPSI, UK Ex |