Product type | Digital liquid level controller |
Function | Measure liquid level, interface liquid level between two liquids, or liquid density (density) |
Communication protocol | Important information for process operations can be easily accessed through the Hart communication protocol |
Settings and Calibration | Simplified settings and calibration that can be configured to use default sensor data, zero level offset, differential process SG, and zero/range only programs, enabling quick replacement of analog transmitters (4-20mA output) |
Startup method | By using the electronic installation wizard, the digital liquid level controller can be easily and quickly started |
Alarm setting | The liquid level and temperature alarm, specific gravity meter, calibration valve trim, and trend can be set at any time |
Product advantage | High gain analog-to-digital conversion accuracy, capable of measuring small changes in the measured variable |
Measurement Principle | Magnetic level sensing, guided wave radar, or ultrasonic (model-dependent). |
Range | Up to12 meters(40 feet) for magnetic models; up to30 meters(100 feet) for radar models. |
Accuracy | ±0.1% of span (magnetic); ±2 mm (radar). |
Temperature Range | -40°C to +150°C (-40°F to +302°F) (varies by sensor type). |
Pressure Rating | Up to40 bar (580 psi)(high-pressure models available). |
Power Supply | 24 VDC (loop-powered) or 10-30 VDC (external supply). |
Output Signals | 4-20 mA, HART®, Modbus RTU, or Ethernet/IP (optional). |
Certifications | ATEX, IECEx (explosion-proof for hazardous areas); CSA, CE, SIL 2/3 (safety applications). |
Mounting Options | Flange-mounted, thread-mounted, or retractable probe design. |