Original and New Emerson 475 Field Communicator

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (18)
  • Original and New Emerson 475 Field Communicator
  • Original and New Emerson 475 Field Communicator
  • Original and New Emerson 475 Field Communicator
  • Original and New Emerson 475 Field Communicator
  • Original and New Emerson 475 Field Communicator
  • Original and New Emerson 475 Field Communicator
Find Similar Products
  • Overview
  • Product Description
  • Installation Instructions
  • Packaging & Shipping
  • Company Profile
  • FAQ
  • Customer Photos
Overview

Basic Info.

Model NO.
475
Application
Chemical Instrument, Thermal Power, Mechanical Instrument, Length Instrument, Time Frequency Instrument, Electromagnetic Instrument, Radio Apparatus
Power
Electricity
Certification
FDA, CE, IAF, CCC
Voltage Output
220V
Current Output
40A
Thermocouple (TC)
K
Resistance-Temperature Detector (RTD)
Pt100(385)
LCD Display
With LCD Display
Customized
Customized
Place of Origin
Singapore
Brand Name
Rosemount
Protection Class
IP67
Model
Rosemount 475 Field Communicator
Communication Protocols
Hart, Foundation Fieldbus
Display
5.7-Inch Color LCD Touchscreen
Power Supply
Rechargeable Lithium-Ion Battery
Operating Temperature
-20°c to 70°c
Storage Temperature
-40°c to 85°c
Dimensions
225 mm X 135 mm X 65 mm
Weight
8.1.25 Kg (with Battery)
Memory
8 GB Internal Storage
Connectivity
USB 2.0, Bluetooth
Battery Life
up to 12 Hours (Continuous Use)
Diagnostics
Advanced Device Health Monitoring
Transport Package
Fast Delivery
Specification
25cm*15cm*10cm
Trademark
Rosemount
Origin
China
HS Code
8517699000
Production Capacity
1000pieces/Year

Product Description

Rosemount 475 Field Communicator
The Rosemount 475 Field Communicator is a versatile, handheld diagnostic and configuration tool designed for use with industrial process instrumentation. Engineered by Emerson Automation Solutions, this device serves as a critical interface for technicians and engineers working with HART, FOUNDATION Fieldbus, and other protocol-enabled field devices. Its primary function is to simplify the setup, calibration, and troubleshooting of smart field instruments, such as pressure transmitters, flow meters, and temperature sensors. The 475 features an intuitive user interface with a high-resolution color touchscreen, enabling quick access to device parameters, real-time process data, and diagnostic information. It supports both wired and wireless connections, including Bluetooth and USB, ensuring compatibility with a wide range of devices in challenging industrial environments. With its rugged, explosion-proof design, the 475 is built to withstand harsh conditions, including extreme temperatures, moisture, and hazardous areas, making it ideal for use in oil and gas, chemical, pharmaceutical, and power generation industries.


All the accessories are available 
Original and New Emerson 475 Field Communicator
Advanced Features and Applications
The Rosemount 475 Field Communicator excels in advanced diagnostics and device management. It enables users to perform loop tests, valve tests, and sensor simulations, streamlining maintenance workflows and reducing downtime. The device supports comprehensive configuration tasks, such as setting measurement ranges, adjusting damping values, and customizing output signals. Its built-in documentation capabilities allow technicians to generate detailed reports, including calibration certificates and audit trails, ensuring compliance with industry standards like ISO 9001. Additionally, the 475 integrates with asset management software such as Emerson's AMS Device Manager, facilitating seamless data transfer and centralized device monitoring. For wireless HART devices, it leverages the WirelessHART protocol to configure and diagnose instruments in hard-to-reach locations without physical connections. The communicator also features multilingual support, firmware update capabilities, and a long-lasting battery, ensuring reliability during extended field operations. By combining user-friendly operation with powerful functionality, the Rosemount 475 enhances operational efficiency, supports predictive maintenance strategies, and extends the lifespan of critical process instrumentation across industrial automation systems.

 

Product Name Rosemount 475 Field Communicator
Brand Rosemount
Model 475
Warranty 1 Year
Product Description
Original and New Emerson 475 Field Communicator
Original and New Emerson 475 Field Communicator
Original and New Emerson 475 Field Communicator
Original and New Emerson 475 Field Communicator
Installation Instructions
Procedure Tools Required Precautions
Ensure the Rosemount 475 Field Communicator is powered off. Verify the battery level (minimum 50% recommended).
 
None
 
Avoid accidental activation.
 
Inspect the communication cable (FOUNDATION Fieldbus or HART protocol compatible) for physical damage.
 
Visual inspection
 
Replace damaged cables immediately.
 
Connect the 475 Field Communicator to the powered field device using appropriate wiring:
- Red clamp: Positive terminal
- Black clamp: Negative terminal
- Green clamp: Ground (if applicable)

 
Wire strippers
Terminal screwdriver

 
Verify proper polarity before connection.
 
Power on the 475 unit. Wait for full initialization (LED status indicator turns solid green).
 
None
 
Do not disconnect during boot sequence (approx. 15 seconds).
 
Select communication protocol from main menu:
1. HART
2. FOUNDATION Fieldbus
3. PROFIBUS PA

 
Stylus/finger input
 
Match protocol to connected device specifications.
 
Navigate to Device Configuration > Auto Detection. Allow 30-60 seconds for protocol handshake.
 
None
 
Maintain stable connection during detection.
 
Confirm device recognition through displayed parameters:
- Manufacturer ID
- Device tag
- Firmware version

 
None
 
Cross-verify with device documentation.
 
Access Basic Setup menu to configure:
1. Measurement units (PSI, bar, kPa, etc.)
2. Output damping (0.1-100 seconds)
3. Failure mode settings

 
Stylus/finger input
 
Save changes before exiting menu.
 
Perform sensor trim calibration:
1. Zero Trim (atmospheric pressure)
2. Upper Range Trim (apply 100% pressure)
3. Lower Range Trim (apply 0% pressure)

 
Pressure source
Calibration standard

 
Use certified reference equipment.
 
Execute valve characterization test for control loop devices:
1. Open-loop response check
2. Step response analysis
3. Dead band measurement

 
None
 
Ensure process is in safe state.
 
Configure alarm thresholds:
1. High process alert
2. Low process alert
3. Rate-of-change alarm

 
Stylus/finger input
 
Adhere to process safety limits.
 
Set communication parameters:
- HART: 1200/9600 baud rate
- FF: Link Active Scheduler (LAS) assignment
- PROFIBUS: Node addressing

 
Network diagram
 
Maintain unique device addresses.
 
Verify configuration through simulation mode:
1. Force analog output (4-20mA)
2. Test digital states
3. Validate HART response codes

 
Multimeter
HART modem

 
Disconnect from live process first.
 
Document configuration changes using the 475's report generation feature:
1. Select "Save As"
2. Choose file format (.PDF/.CSV)
3. Transfer via USB or Bluetooth

 
USB cable
PC with AMS Suite

 
Archive previous configurations.
 
Perform loop integrity check:
1. Measure loop resistance (20-1000Ω)
2. Verify supply voltage (12-42VDC)
3. Check signal noise (max 20mV p-p)

 
Digital multimeter
Oscilloscope

 
Comply with intrinsic safety requirements.
 
Update firmware via Device Maintenance menu:
1. Download latest version from Rosemount
2. Transfer via USB
3. Confirm checksum validation

 
USB flash drive
Internet connection

 
Do not interrupt update process.
 
Implement security settings:
1. Password protection (4-16 characters)
2. User access levels
3. Audit trail activation

 
None
 
Record credentials securely.
 
Conduct final functional test:
1. Process variable monitoring
2. Control signal output verification
3. Diagnostic parameter review

 
Process calibrator
Digital analyzer

 
Confirm all process connections restored.
 
Disconnect 475 Field Communicator:
1. Power off unit
2. Remove test leads
3. Secure protective caps

 
None
 
Follow electrostatic discharge (ESD) protocols.
 
Store unit in approved carrying case. Maintain operating temperature range (-20°C to 55°C).
 
Protective case
 
Avoid prolonged exposure to moisture.
 

 

Packaging & Shipping

Original and New Emerson 475 Field CommunicatorOriginal and New Emerson 475 Field Communicator

Company Profile

Original and New Emerson 475 Field Communicator

 

FAQ

Q: How long will you to give me the reply?
A: We will reply to you as soon as we see the information

Q: What is the delivery time?
A: The products in stock will be shipped after receiving the payment, and the products that
need to be ordered are subject to the factory's time.

Q: How about your package?
A: Do not worry about the package, we have rich experience in packing.

Q: How about the payment terms?
A: You can choose T/T.

Q: What is the MOQ?
A:1PC.

Q: Can I get a lower price if l order large quantities?
A: Yes, cheaper prices with more bigger size orders.

Q: After sales and warranty?