New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments

Product Details
Customization: Available
Type: Network Type
Measuring Medium: Temperature
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (18)
  • New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments
  • New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments
  • New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments
  • New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments
  • New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments
  • New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Installation Instructions
  • Company Profile
  • Packaging & Shipping
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
644 Rail Temperature
Display Type
LED
Site Display
Site Display
Accuracy
0.5
IP Rating
IP67
Certification
CE
Customized
Customized
Place of Origin
China
Warranty
1 Year
Customized Support
OEM, ODM
Brand Name
Rosemount
Mounting Styles
DIN a Head, Field, Rail Mount
Stability
5-Year Stability
Display
LCD with Local Operator Interface (Loi)
Input
Rtd, Thermocouple, Mv, Ohms (Single/Dual)
Output
4-20mA/Hart, Digital Protocol
Enclosure
Aluminum/Stainless Steel IP66/IP68
Certifications
Sil2/3, ATEX, Iecex, FM
Temperature Range
Temperature Range
Compensation
Ambient Temperature Compensation
Calibration
3-Point Calibration Certificate
Communication
Hart 375/475 Handheld, AMS Device Manager
Transport Package
100% Original Package
Specification
20cm*25cm*25cm
Trademark
Rosemount
Origin
China
HS Code
9025191090
Production Capacity
10000pieces/Year

Packaging & Delivery

Package Size
20.00cm * 25.00cm * 25.00cm
Package Gross Weight
1.000kg

Product Description

Product Description

Rosemount 644 Rail-Mounted Temperature Transmitter
The Rosemount 644 Rail-Mounted Temperature Transmitter is a state-of-the-art solution designed for precise and reliable temperature measurement in industrial applications. Engineered by Emerson, this transmitter integrates advanced sensing technology with robust construction to deliver high accuracy across a wide range of process conditions. It supports various temperature sensor inputs, including RTDs (Resistance Temperature Detectors) and thermocouples, and converts these signals into standardized 4-20 mA or digital outputs for seamless integration with control systems. The device is optimized for DIN rail mounting, offering a compact and space-efficient design that simplifies installation in control cabinets or panels. Built to withstand harsh environments, the Rosemount 644 features exceptional durability, with certifications for hazardous areas (ATEX, IECEx, FM) and compliance with global safety standards. Its user-friendly interface, combined with diagnostic capabilities, enables proactive maintenance and reduces downtime, making it ideal for industries such as oil and gas, chemical processing, power generation, and pharmaceuticals.
Technical Excellence and Application Versatility
The Rosemount 644 excels in delivering unmatched measurement accuracy, with a typical precision of ±0.1% of span, ensuring reliable data for critical processes. Its advanced signal conditioning technology minimizes errors caused by electrical noise, temperature fluctuations, or sensor degradation. The transmitter supports HART® 7 communication protocols, allowing for remote configuration, real-time monitoring, and diagnostics via compatible software tools like AMS Device Manager. Additionally, its modular design enables easy customization with optional features such as isolated outputs, LCD displays, and custom scaling. The device's robust construction includes a high-impact polymer housing and corrosion-resistant materials, ensuring longevity in extreme temperatures (-40°C to 85°C ambient) and humid or corrosive environments. With its global certifications and compatibility with industry-standard communication protocols like Foundation Fieldbus and PROFIBUS PA, the Rosemount 644 is a versatile choice for modern automation systems. Its ability to enhance process efficiency, reduce calibration cycles, and improve operational safety makes it a cornerstone in temperature measurement solutions worldwide.

Detailed Photos
New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments
New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments
New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments
New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments
Installation Instructions
Description
 
Details
 
Product Overview
 
Rosemount 644 Rail Temperature Transmitter is designed for rail-mounted installation, providing accurate temperature measurement in industrial environments. Compatible with various RTD and thermocouple sensors. Key features include HART communication, LCD display, and robust construction.
 
Safety Precautions
 
- Verify power supply matches 10.5-55 VDC.
- Ensure proper grounding.
- Disconnect power before wiring.
- Avoid exposure to corrosive substances.
- Follow local electrical codes.

 
Unboxing & Components
 
Included items:
- Rosemount 644 Transmitter
- Terminal block
- Installation manual
- Rail mounting clip
- Certification documents
- Optional: explosion-proof housing (if ordered).

 
Mounting
 
1. Attach DIN rail clip to transmitter.
2. Snap transmitter onto 35 mm DIN rail.
3. Tighten mounting screw to 0.9 N·m torque.
4. Ensure vertical orientation for optimal heat dissipation.

 
Wiring Connections
 
Terminal Block Layout (TB1):
- Terminals 1-2: Sensor input (RTD/TC)
- Terminals 3-4: Power supply (10.5-55 VDC)
- Terminals 5-6: HART communication (optional)
Use shielded twisted-pair cables for sensor connections. Max wire length: 100 meters.

 
Sensor Configuration
 
1. Remove front cover using 3 mm hex key.
2. Set DIP switches (SW1) per sensor type:
- RTD: Set to Pt100, Pt500, or Pt1000
- Thermocouple: Select J/K/T/E/R/S/B type
3. Verify jumper settings for 2/3/4-wire RTD connections.

 
Power Up & Initialization
 
1. Apply 24 VDC power.
2. Wait 15 seconds for initialization.
3. LCD displays sensor type, temperature value, and status code. Normal status: "OK".

 
LCD Interface Navigation
 
Button Functions:
- MODE: Cycle through parameters
- UP/DOWN: Adjust values
- ENTER: Confirm selection
Display Modes:
- Primary: Process temperature
- Secondary: Output current/percentage

 
HART Communication Setup
 
1. Connect HART modem to terminals 5-6.
2. Use Rosemount 375/475 Field Communicator or AMS Suite.
3. Device address: Set to 0 for single-device networks.
4. Configure:
- PV units (°C/°F/K)
- Damping time (0-60 sec)
- Fail-safe mode (upscale/downscale)

 
Calibration Procedure
 
1. Access calibration menu via HART device.
2. Apply known temperature reference.
3. Select "Trim Sensor" for sensor calibration.
4. Select "Trim Output" for 4-20 mA adjustment.
5. Follow on-screen prompts to complete trimming.

 
Range Configuration
 
Using HART Communicator:
1. Set LRV (Lower Range Value)
2. Set URV (Upper Range Value)
Example: 0°C (4 mA) to 200°C (20 mA)
Note: Must match DIP switch sensor type selection.

 
Diagnostics & Troubleshooting
 
Common Error Codes:
- E001: Sensor open circuit
- E002: Sensor short circuit
- E003: Out of range
- E004: Configuration error
Corrective Actions:
- Verify sensor connections
- Check DIP switch settings
- Confirm input within sensor specification

 
Company Profile

New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments

Packaging & Shipping

New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial EnvironmentsNew Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial EnvironmentsNew Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial EnvironmentsNew Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments

Certifications

New Rosemount 644 High-Precision Rail Temperature Transmitter for Harsh Industrial Environments

FAQ

You may have this questions

Q: How long will you give me the reply?
A: We will reply to you as soon as we see the information
 
Q: What is the delivery time?
A:The products in stock will be shipped after receiving the payment, and the products that
need to be ordered are subject to the factory time.
 
Q: How about your package?
A: Do not worry about the package, we have rich experience in packing.
 
Q: How about the payment terms?
A:You can choose T/T.
 
Q: What is the MOQ?
A:1PC.
 
Q: Can l get a lower price if l order large quantities?
A: Yes, cheaper prices with more bigger size orders.
 
Q:After sales and warranty?
A: We provide one year warranty lifetime technical support services.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier