Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter

Product Details
Customization: Available
After-sales Service: One-Year Warranty
Warranty: 1 Year
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (18)
  • Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter
  • Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter
  • Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter
  • Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter
  • Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter
  • Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
8600DF040/8600DF060/8600DF080
Accuracy
±0.2-0.5%
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size
DN100-500
Sensor
Tube/Flange
Application
Energy Metering
Type
Vortex Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Open Channel
Certification
CE
Item Name
Rosemount 8600df Vortex Flow Meter
MOQ
1PC
Place of Origin
USA
Flow Rate
0.5-12m/S
Material
Stainless Steel
Medium
Water, Oil, Liquid, Gas, Air
Connectivity
Flange
Brand Name
Rosemounte
Model Number
8600df
Customized Support
OEM, ODM, Obm
Operating Temperatures
-58 to 185 °f
Output Signals
4-20 Ma Hart Digital Signal
Flanged Style
1, 11/2, 2, 3, 4, 6, and 8 Inches
Storage
-58 to 250 °f
Single Gross Weight
8.600 Kg
Transport Package
Carton Boxes
Specification
40X30X30 cm
Trademark
Rosemount
Origin
Singapore
HS Code
9026100000
Production Capacity
100/Month

Packaging & Delivery

Package Size
45.00cm * 40.00cm * 30.00cm
Package Gross Weight
9.000kg

Product Description

Product Description
The Rosemount 8600DF Vortex Flow Meter is a highly advanced and reliable instrument designed for accurate flow measurement in a wide range of industrial applications. Manufactured by Emerson, a globally recognized leader in automation solutions, the 8600DF series combines cutting-edge technology with robust construction to deliver outstanding performance and long-term durability.
Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter
The 8600DF offers excellent accuracy, making it suitable for applications where precise flow measurement is crucial. For liquids, it can achieve an accuracy of ± 0.75% of the volumetric rate. In the case of gas and steam, the accuracy is ± 1% of the volumetric rate. When using the 8600 multivariable (MTA option) for mass flow measurement of steam, the accuracy is ± 2% of the rate. This high level of accuracy ensures reliable process control, efficient resource management, and accurate billing in various industries.With a turndown ratio of 30:1, the Rosemount 8600DF can effectively measure flows over a broad range. This means it can accurately handle both low and high flow rates within the same installation, eliminating the need for multiple flow meters or complex flow range switching systems. Whether the application involves a small trickle of fluid or a high - velocity stream, the 8600DF can provide accurate measurements, enhancing its versatility and adaptability to different operating conditions.

Features

One of the significant advantages of the 8600DF is its design without any moving parts in the flow path. This not only reduces the risk of mechanical failure but also minimizes maintenance requirements. Without the need to replace worn - out moving components, the meter offers enhanced reliability and a longer service life. Additionally, the absence of moving parts means there are no potential sources of leakage, ensuring a safe and secure operation in applications where fluid containment is critical.The sensor system of the 8600DF features an innovative mass - balanced structure and incorporates advanced adaptive digital signal processing (ADSP) technology. These design elements work in tandem to provide exceptional vibration immunity. In industrial environments where mechanical vibrations are common, such as in plants with large machinery or in pipelines subject to external forces, the 8600DF can maintain accurate measurements without being affected by the vibrations. This stability ensures consistent performance and reduces the likelihood of measurement errors caused by external disturbances.
 
Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter

Product Overview

Installation of the Rosemount 8600DF is straightforward and hassle - free. It does not require impulse lines, which are often complex and prone to blockages in traditional flow measurement systems. This inline technology eliminates the need for elaborate piping arrangements and reduces the risk of leaks associated with impulse lines. Moreover, the meter does not need field calibration or zeroing during installation, saving time and effort for the installation team. The internal verification of both the electronics and the sensor also provides enhanced process insight from the moment of installation.The 8600DF is equipped with electronics verification capabilities, which simplify the troubleshooting process. In the event of a measurement issue or a suspected malfunction, technicians can use the built - in diagnostic tools to quickly identify the source of the problem. Whether it is a problem with the sensor, the electronics, or the communication interface, the meter can provide valuable information to assist in resolving the issue promptly. This not only minimizes downtime but also reduces the cost associated with maintenance and repair.The 8600DF offers the option of remote - mount electronics, which is particularly useful in applications where access to the flow meter location is difficult or where environmental conditions may be harsh. By separating the electronics from the sensor unit and mounting them in a more accessible or protected location, operators can easily monitor and configure the meter. This also provides flexibility in installation, allowing for better integration with existing control systems and infrastructure.The 8600DF is available with a range of flange options to accommodate different piping standards and installation requirements. Flange options include ANSI class 150 and 300, as well as DIN PN 10 and PN 40. This variety of flange choices allows for easy integration of the flow meter into existing pipelines in different industries and regions around the world. The flanges are designed to provide a secure and leak - tight connection, ensuring proper operation of the flow meter within the piping system.

Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter

Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter
Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter
Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter
Product Parameters
Accuracy ±1% Measurement Range other
Type Other Material Stainless Steel
Place of Origin Shandong, China Medium liquid, Gas, and slurry
Single Package Size 40X30X30 cm Connectivity Flange
Warranty 1 Year Customized Support OEM, ODM
Brand Name Emerson Model Number 8600DF040
Place of Origin China Customized Support OEM
Brand Name Rosemounte Model Number 8600D
Warranty 1 Year Type vortex flowmeter
Process Temperature Limits -58 to 482 °F Output Signals 4-20 mA HART digital signal
Enclosure Rating FM Type 4X IP66 Single Gross Weight 8.600 KG
 
Packaging & Shipping

Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter

Carton Boxes
Company Profile

KeRui (Weifang) Automation Equipment Co., Ltd.Specializes in industrial automation instrument development, production and sales, technical services, and supporting equipment supply to specialized companies. The main products are flow meters, level meters, temperature meters, pressure meters, electrical meters, thermal intelligent meters, programmable controllers (PLC), DCS distributed control systems, and eight series of more than 1,000 specifications. Its products and technologies are widely used in electric power, metallurgy, petrochemicals, environmental protection, plastics, food, printing, tobacco, textile, dyeing, and other fields.Original Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow MeterOriginal Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow MeterOriginal Emerson Rosemount 8600 Series 8600df040/8600df060/8600df080 Utility Vortex Flow Meter

FAQ

1.Q: How long is the delivery?
 -- Mostly within 10days
 2.Q:Can I get a sample? 
 --  Sure, contact our sales please
 3.Q:What is your MOQ? 
 
--  1pcs
 4.Q: How about warranty time? 
 
-- 12month
 5.Q: How can I visit your factory?
 -- Fly to Qingdao air port, it's our pleasure to pick you up.
 6.Q:How do you control your quality ? 
 -- We have EPR system .we control from parts, process, testing, packing ,retesting.
 Every Sensor will be tested two times before reach you, after that sport test for the third time. Make sure about the quantity.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier