Basic Info.
Model NO.
475 Field Communicator
After-sales Service
1 Year
Application
Chemical Instrument, Thermal Power, Mechanical Instrument, Length Instrument, Time Frequency Instrument, Electromagnetic Instrument, Radio Apparatus
Resistance-Temperature Detector (RTD)
Pt100(385)
LCD Display
With LCD Display
Place of Origin
Singapore
Model
Rosemount 475 Field Communicator
Communication Protocols
Hart, Foundation Fieldbus
Display
5.7-Inch Color LCD Touchscreen
Power Supply
Rechargeable Lithium-Ion Battery
Operating Temperature
-20°c to 70°c
Storage Temperature
-40°c to 85°c
Dimensions
225 mm X 135 mm X 65 mm
Weight
8.1.25 Kg (with Battery)
Memory
8 GB Internal Storage
Connectivity
USB 2.0, Bluetooth
Battery Life
up to 12 Hours (Continuous Use)
Diagnostics
Advanced Device Health Monitoring
Transport Package
Fast Delivery
Specification
25cm*15cm*10cm
Product Description
Rosemount 475 Field Communicator
The Rosemount 475 Field Communicator is a versatile, handheld diagnostic and configuration tool designed for use with industrial process instrumentation. Engineered by Emerson Automation Solutions, this device serves as a critical interface for technicians and engineers working with HART, FOUNDATION Fieldbus, and other protocol-enabled field devices. Its primary function is to simplify the setup, calibration, and troubleshooting of smart field instruments, such as pressure transmitters, flow meters, and temperature sensors. The 475 features an intuitive user interface with a high-resolution color touchscreen, enabling quick access to device parameters, real-time process data, and diagnostic information. It supports both wired and wireless connections, including Bluetooth and USB, ensuring compatibility with a wide range of devices in challenging industrial environments. With its rugged, explosion-proof design, the 475 is built to withstand harsh conditions, including extreme temperatures, moisture, and hazardous areas, making it ideal for use in oil and gas, chemical, pharmaceutical, and power generation industries.
Advanced Features and Applications
The Rosemount 475 Field Communicator excels in advanced diagnostics and device management. It enables users to perform loop tests, valve tests, and sensor simulations, streamlining maintenance workflows and reducing downtime. The device supports comprehensive configuration tasks, such as setting measurement ranges, adjusting damping values, and customizing output signals. Its built-in documentation capabilities allow technicians to generate detailed reports, including calibration certificates and audit trails, ensuring compliance with industry standards like ISO 9001. Additionally, the 475 integrates with asset management software such as Emerson's AMS Device Manager, facilitating seamless data transfer and centralized device monitoring. For wireless HART devices, it leverages the WirelessHART protocol to configure and diagnose instruments in hard-to-reach locations without physical connections. The communicator also features multilingual support, firmware update capabilities, and a long-lasting battery, ensuring reliability during extended field operations. By combining user-friendly operation with powerful functionality, the Rosemount 475 enhances operational efficiency, supports predictive maintenance strategies, and extends the lifespan of critical process instrumentation across industrial automation systems.
Product Description
Product Name | Rosemount 475 Field Communicator |
Brand | Rosemount |
Model | 475 |
Warranty | 1 Year |
Installation Instructions
Procedure | Tools Required | Precautions |
Ensure the Rosemount 475 Field Communicator is powered off. Verify the battery level (minimum 50% recommended). | None | Avoid accidental activation. |
Inspect the communication cable (FOUNDATION Fieldbus or HART protocol compatible) for physical damage. | Visual inspection | Replace damaged cables immediately. |
Connect the 475 Field Communicator to the powered field device using appropriate wiring: - Red clamp: Positive terminal - Black clamp: Negative terminal - Green clamp: Ground (if applicable) | Wire strippers Terminal screwdriver | Verify proper polarity before connection. |
Power on the 475 unit. Wait for full initialization (LED status indicator turns solid green). | None | Do not disconnect during boot sequence (approx. 15 seconds). |
Select communication protocol from main menu: 1. HART 2. FOUNDATION Fieldbus 3. PROFIBUS PA | Stylus/finger input | Match protocol to connected device specifications. |
Navigate to Device Configuration > Auto Detection. Allow 30-60 seconds for protocol handshake. | None | Maintain stable connection during detection. |
Confirm device recognition through displayed parameters: - Manufacturer ID - Device tag - Firmware version | None | Cross-verify with device documentation. |
Access Basic Setup menu to configure: 1. Measurement units (PSI, bar, kPa, etc.) 2. Output damping (0.1-100 seconds) 3. Failure mode settings | Stylus/finger input | Save changes before exiting menu. |
Perform sensor trim calibration: 1. Zero Trim (atmospheric pressure) 2. Upper Range Trim (apply 100% pressure) 3. Lower Range Trim (apply 0% pressure) | Pressure source Calibration standard | Use certified reference equipment. |
Execute valve characterization test for control loop devices: 1. Open-loop response check 2. Step response analysis 3. Dead band measurement | None | Ensure process is in safe state. |
Configure alarm thresholds: 1. High process alert 2. Low process alert 3. Rate-of-change alarm | Stylus/finger input | Adhere to process safety limits. |
Set communication parameters: - HART: 1200/9600 baud rate - FF: Link Active Scheduler (LAS) assignment - PROFIBUS: Node addressing | Network diagram | Maintain unique device addresses. |
Verify configuration through simulation mode: 1. Force analog output (4-20mA) 2. Test digital states 3. Validate HART response codes | Multimeter HART modem | Disconnect from live process first. |
Document configuration changes using the 475's report generation feature: 1. Select "Save As" 2. Choose file format (.PDF/.CSV) 3. Transfer via USB or Bluetooth | USB cable PC with AMS Suite | Archive previous configurations. |
Perform loop integrity check: 1. Measure loop resistance (20-1000Ω) 2. Verify supply voltage (12-42VDC) 3. Check signal noise (max 20mV p-p) | Digital multimeter Oscilloscope | Comply with intrinsic safety requirements. |
Update firmware via Device Maintenance menu: 1. Download latest version from Rosemount 2. Transfer via USB 3. Confirm checksum validation | USB flash drive Internet connection | Do not interrupt update process. |
Implement security settings: 1. Password protection (4-16 characters) 2. User access levels 3. Audit trail activation | None | Record credentials securely. |
Conduct final functional test: 1. Process variable monitoring 2. Control signal output verification 3. Diagnostic parameter review | Process calibrator Digital analyzer | Confirm all process connections restored. |
Disconnect 475 Field Communicator: 1. Power off unit 2. Remove test leads 3. Secure protective caps | None | Follow electrostatic discharge (ESD) protocols. |
Store unit in approved carrying case. Maintain operating temperature range (-20°C to 55°C). | Protective case | Avoid prolonged exposure to moisture. |
Packaging & Shipping
Company Profile
FAQ
Q: How long will you give me the reply?
A: We will reply to you as soon as we see the information
Q: What is the delivery time?
A:The products in stock will be shipped after receiving the payment, and the products that
need to be ordered are subject to the factory time.
Q: How about your package?
A: Do not worry about the package, we have rich experience in packing.
Q: How about the payment terms?
A:You can choose T/T.
Q: What is the MOQ?
A:1PC.
Q: Can l get a lower price if l order large quantities?
A: Yes, cheaper prices with more bigger size orders.
Q:After sales and warranty?
A: We provide one year warranty lifetime technical support services.
Customer Photos
Address:
N/a, Weifang, Shandong, China
Business Type:
Trading Company
Business Range:
Instruments & Meters
Company Introduction:
Different kinds of products are available in our company. We′re pleased to get your Inquiry and we will reply you as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective.